The GLO annealing furnace features a vacuum tight retort with highly symmetric positioning of the heating elements. The heating elements are CrFeAl, also known as APM, and are embedded in the ceramic fibre insulation.

The GLO is often equipped with a vacuum pumping system to reduce the Oxygen levels prior to heat treatment. To ensure the lowest possible contamination levels, several cycles of vacuum and Nitrogen purging occur to create a pure atmosphere in the retort. Vacuum assisted cycling is far superior compared to simply flowing Nitrogen through the retort as the process creates a pure atmosphere faster and requires less Nitrogen. After Oxygen levels have been reduced, heat treatment begins under an inert atmosphere with a slight overpressure.

The highest possible temperature of the GLO annealing furnace is 1100℃ for heat treatment with an atmosphere. The front door of the cylindrical retort can be heated if required. At the water cooled front door, the gas is purged inside the GLO. It is preheated by the radiation shields, which are inserted at the front. The GLO is provided with a rear port for the expulsion of any gaseous by-products generated during the process.

The GLO can be operated manually or with the use of an automated system. The furnace is available in sizes of 10 (mobile version), 40, 75, 120 and 260 litres. The retort is manufactured with temperature resistant steel alloy (1.4841). Other materials are available on request.

The annealing furnace may be operated with reactive gases such as Hydrogen, which requires appropriate safety technology. The Hydrogen safety system includes an automatic operating system with a Nitrogen flooding tank to detect and purge the system should any malfunctions be detected. All devices are SIL2 certified.

The furnaces have a compact, space saving design. The debinding package allows for debinding or pyrolysis processes to be carried out. Virtually no condensation occurs as the unit is equipped with an afterburner and heated gas outlet for strong outgassing applications.

The GLO can be equipped with a fast cooling system. The retort can be air cooled from the outside or purged with cold, inert gas.

The GLO furnace is also available in two alternative versions: 
The vertical VGLO is loaded vertically and therefore provides a compact, space saving design.
The mobile GLO is a transportable, space-saving version for flexible use in different applications.


应用实例

annealing, degassing, drying, glowing, hardening, pyrolysis, tempering, thermal debinding prior to sintering


标准参数

Precisely controlled atmosphere with highest possible purity

Sealed retort for highest vacuum possible

Fast heat up and cool down options upon request

Hydrogen partial pressure operation upon request

Afterburner

Certified safety management for flammable and toxic gases

Fully automatic operation or manual operation

Data recording for quality management


选项(订购时详细标注要求)

Vacuum System: pre-vacuum pump, roots pump, or turbomolecular pump

Different software and controller options like Eurotherm 3508, Siemens, iTools, over-temperature protection or remote control available

Reaction gas equipment for hydrogen concentrations larger than 4%

Chiller in case no water cooling is available on-site


技术参数

View inside of the annealing furnace:

    opened door

    radiation shields

    ceramic fiber insulation and heating elements

    charging rack

    thin metallic sourrounding

    afterburner

    frame


The maximum temperature of the GLO annealing furnace is 1100℃. In this temperature range, heat is transmitted via a high amount of heat convection and conduction.

To ensure excellent temperature uniformity, the furnace is equipped with a gas circulation system by means of a ventillator located at the rear of the furnace, which ensures that the sample is surrounded by uniform inert gas at all times.

The sample specimen is placed on an engineered, horizontal charging rack with the incoming gases guided over the sample. Any gaseous by-products generated are immediately flushed out of the furnace.

A probe thermocouple is positioned at the rear of the furnace and in close proximity to the samples. The probe thermocouple serves as the control thermocouple for the two heating zones of the GLO, and simultaneously, monitors the temperature directly at the sample.

The heating elements are located outside of the retort. An over-temperature thermocouple is used for unattended operation. Further thermocouple probes can be integrated into the retort upon request.

内容可能会被修改或更正。

GLO 10/11-1G

Volume (l)10
Tmax vacuum (°C)600
Tmax atmospheric pressure (°C)600 / 900 / 1100
尺寸: 外部 高 x 宽 x 纵深 (mm)1800 x 850 x 1600
Transport weight
Complete system (kg)500
Usable space
Ø x D (mm)250 x 300
Thermal values
ΔT between 300 and 1100°C (K) according to DIN 17052± 5
Max. heat-up rate (K/min)10
Cooling time (h)4 - 5
Connecting values
Power (kW)14
Voltage (V)400 (3P)
Current (A)3 x 25
Series fuse (A)3 x 32
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s)< 5x10-3
Vacuum range depending on the pumping unitrough, fine or high vacuum
Cooling water required
Flow (l/min)1-3
Max. inlet temperature (°C)23
Gas supply
Nitrogen or Argon flow, others on request (l/h)200-2000
Controller
Manual operationEurotherm
Automatic operationSiemens

VGLO-TL 10/11-1G

Volume (l)10
Tmax vacuum (°C)600
Tmax atmospheric pressure (°C)600 / 900 / 1100
尺寸: 外部 高 x 宽 x 纵深 (mm)1600 (open) x 1400 x 850
Transport weight
Complete system (kg)500
Usable space
Ø x D (mm)250 x 250
Thermal values
ΔT between 300 and 1100°C (K) according to DIN 17052± 5
Max. heat-up rate (K/min)10
Cooling time (h)4 - 5
Connecting values
Power (kW)14
Voltage (V)400 (3P)
Current (A)3 x 25
Series fuse (A)3 x 32
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s)< 5x10-3
Vacuum range depending on the pumping unitrough, fine or high vacuum
Cooling water required
Flow (l/min)1-3
Max. inlet temperature (°C)23
Gas supply
Nitrogen or Argon flow, others on request (l/h)200-2000
Controller
Manual operationEurotherm
Automatic operationSiemens

GLO 40/11-1G

Volume (l)40
Tmax vacuum (°C)600
Tmax atmospheric pressure (°C)600 / 900 / 1100
尺寸: 外部 高 x 宽 x 纵深 (mm)1900 x 1400 x 1800
Transport weight
Complete system (kg)1200
Usable space
Ø x D (mm)300 x 600
Thermal values
ΔT between 300 and 1100°C (K) according to DIN 17052± 3
Max. heat-up rate (K/min)10
Cooling time (h)7 - 9
Connecting values
Power (kW)25
Voltage (V)400 (3P)
Current (A)3 x 63
Series fuse (A)3 x 80
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s)< 5x10-3
Vacuum range depending on the pumping unitrough, fine or high vacuum
Cooling water required
Flow (l/min)1-3
Max. inlet temperature (°C)23
Gas supply
Nitrogen or Argon flow, others on request (l/h)200-2000
Controller
Manual operationEurotherm with KP 300 panel
Automatic operationSiemens

GLO 75/11-1G

Volume (l)75
Tmax vacuum (°C)600
Tmax atmospheric pressure (°C)600 / 900 / 1100
尺寸: 外部 高 x 宽 x 纵深 (mm)2000 x 1600 x 1800
Transport weight
Complete system (kg)1500
Usable space
Ø x D (mm)400 x 600
Thermal values
ΔT between 300 and 1100°C (K) according to DIN 17052± 3
Max. heat-up rate (K/min)10
Cooling time (h)7 - 9
Connecting values
Power (kW)40
Voltage (V)400 (3P)
Current (A)3 x 110
Series fuse (A)3 x 160
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s)< 5x10-3
Vacuum range depending on the pumping unitrough, fine or high vacuum
Cooling water required
Flow (l/min)1-3
Gas supply
Nitrogen or Argon flow, others on request (l/h)200-2000
Controller
Manual operationEurotherm with KP 300 panel
Automatic operationSiemens

GLO 120/11-1G

Volume (l)120
Tmax vacuum (°C)600 / 750
Tmax atmospheric pressure (°C)600 / 900 / 1100
尺寸: 外部 高 x 宽 x 纵深 (mm)2100 x 1800 x 2000
Transport weight
Complete system (kg)2000
Usable space
Ø x D (mm)500 x 700
Thermal values
ΔT between 300 and 1100°C (K) according to DIN 17052± 5
Max. heat-up rate (K/min)10
Cooling time (h)8 - 10
Connecting values
Power (kW)45
Voltage (V)400 (3P)
Current (A)3 x 67
Series fuse (A)3 x 80
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s)< 5x10-3
Vacuum range depending on the pumping unitrough, fine or high vacuum
Cooling water required
Flow (l/min)5-10
Max. inlet temperature (°C)23
Gas supply
Nitrogen or Argon flow, others on request (l/h)200-3000
Controller
Manual operationEurotherm with KP 300 panel
Automatic operationSiemens

GLO 260/11-1G

Volume (l)260
Tmax vacuum (°C)600 / 750
Tmax atmospheric pressure (°C)600 / 900 / 1100
尺寸: 外部 高 x 宽 x 纵深 (mm)2100 x 1800 x 2000
Transport weight
Complete system (kg)3000
Usable space
Ø x D (mm)650 x 800
Thermal values
ΔT between 300 and 1100°C (K) according to DIN 17052± 5
Max. heat-up rate (K/min)10
Cooling time (h)10 - 12
Connecting values
Power (kW)70
Voltage (V)400 (3P)
Current (A)3 x 110
Series fuse (A)3 x 125
Vacuum (option)
Leakage rate - clean, cold and empty (mbar l/s)< 5x10-3
Vacuum range depending on the pumping unitrough, fine or high vacuum
Cooling water required
Flow (l/min)10-15
Max. inlet temperature (°C)23
Gas supply
Nitrogen or Argon flow, others on request (l/h)300-3000
Controller
Manual operationEurotherm with KP 300 panel
Automatic operationSiemens

内容可能会被修改或更正。

用户评论
产品评分
目前评分共0人
产品质量
售后服务
易用性
性价比
产品评论
已有0条评论
可以输入500字 
暂无评论!
弗尔德(VERDER)仪器
电话: 点击&查看
联系人: 销售部
邮编: 201204
地址: 上海张江高科技园区毕升路299弄富海商务苑(一期)8栋
同品牌产品:
相关产品:
猜您感兴趣
换一批
ZNH-100 真空捏合机
盘阀
实验室单螺杆挤出机
Q611TC气动三片式V型陶瓷球阀
飞机千斤顶
来访登记
关闭
请留下您的联系方式,登记完成即可查看电话与供应商联系,或等候供应商联系您。
留言类型:
     
*姓名:
*电话:
*单位:
Email:
*留言内容:
请说明需求数量,型号规格以及纯度含量等要求。
*验证码: